Additional information
Weight | 32 kg |
---|---|
Dimensions | 39 × 28 × 700 cm |
Watts | 28kw |
Flue Options | Boiler Only – NO Flue, Vaillant STD Horizontal Flue Kit 100mm (303933), Vaillant Vertical Flue Kit (20223472) |
From £1,525.00
The ecoTEC pro range of combination boilers combine the built-in quality, reliability and performance you’d expect from Vaillant, with a simple design and approach.
The range features 24, 28 and 30kW models, making this boiler perfect for homes with a smaller heating and hot water requirements.
At Vaillant we are working towards low carbon solutions today. As part of the HyDeploy project, Vaillant boilers have been tested with up to 20% hydrogen blended with Natural Gas, and we are currently undergoing many tests to each of our boilers to validate their compatibility with up to 20% hydrogen.
*2 years out the box guarantee. 7 year free extended guarantee available when registered through Vaillant Advance.
Weight | 32 kg |
---|---|
Dimensions | 39 × 28 × 700 cm |
Watts | 28kw |
Flue Options | Boiler Only – NO Flue, Vaillant STD Horizontal Flue Kit 100mm (303933), Vaillant Vertical Flue Kit (20223472) |
Technical data | Unit of measure | ecoTEC pro 24 | ecoTEC pro 28 | ecoTEC pro 28 LPG | ecoTEC pro 30 |
---|---|---|---|---|---|
General | |||||
Boiler type | combi | combi | combi | combi | |
Article number | 0010021836 | 0010021837 | 0010021838 | 0010016538 | |
Gas Council number | 47-044-88 | 47-044-89 | 47-044-90 | 47-044-52 | |
Boiler dimensions (HxWxD) | mm | 720 x 440 x 338 | 720 x 440 x 338 | 720 x 440 x 338 | 720 x 440 x 338 |
Heating | |||||
Nominal heat output range at 50/30ËšC (Condensing mode) | kW | 5.9 – 24.8 | 5.9 – 25.9 | 6.9 – 25.3 | 6.9 – 25.7 |
Nominal heat output range at 80/60ËšC (Non condensing mode) | kW | 5.2 – 23.0 | 5.2 – 24.0 | 7.2 – 24.0 | 6.2 – 24.4 |
Maximum flow temperature | ËšC | 85 | 85 | 85 | 85 |
Flow temperature range | ËšC | 30 – 85 | 30 – 85 | 30 – 85 | 30 – 85 |
Flow temperature factory setting | ËšC | 75 | 75 | 75 | 75 |
Approximate condensate volume at 50/30ËšC | litres/hr | 1.9 | 1.9 | 1.9 | 2:5 |
Modulation (max/min) | 1 : X | 1:4.3 | 1:5 | 1:3.6 | 1:3.8 |
Domestic Hot Water | |||||
Maximum heat output for water generation | kW | 23.4 | 27.2 | 27.2 | 30 |
Lowest water pressure to operate boiler | bar | 0.8 | 0.8 | 0.8 | 0.8 |
Lowest water flow for operation | l/min | 2.0 | 2.0 | 2.0 | 2.0 |
Lowest water pressure for maximum flow rate | bar | 0.8 | 0.8 | 0.8 | 0.8 |
Domestic hot water flow rate (at DT = Δ35K) * | l/min | 9.6 | 11.1 | 11.1 | 12.3 |
Hot water output temperature range | ËšC | 35 – 65 | 35 – 65 | 35 – 65 | 35 – 65 |
Mechanical | |||||
Expansion vessel size | lites | 8 | 8 | 8 | 8 |
Gas inlet connection (pipe size) | mm | 15 | 15 | 15 | 15 |
Heating flow and return connections (pipe size) | mm | 22 | 22 | 22 | 22 |
Hot and cold water connections (pipe size) | mm | 15 | 15 | 15 | 15 |
Heat exchanger material | Stainless/Aluminium | Stainless Steel | Stainless Steel | Stainless Steel | Stainless Steel |
Boiler lift weight (Dry boiler) | kg | 38 | 38 | 38 | 39 |
Performance | |||||
NOx | 5 | 5 | 5 | 5 | |
Nox (En 15502-2-1) | mg/kWh | 27 | 27 | 28 | 30 |
ErP efficiency | % | 94 | 94 | 94 | 93 |
ErP decibel rating (sound power) | dBa | 49 | 49 | 49 | 49 |
Fluing options | |||||
Maximum horizontal flue length 60/100 | m | 12 | 12 | 12 | 12 |
Maximum vertical flue length 60/100 | m | 16 | 16 | 16 | 16 |
Maximum horizontal flue length 80/125 | m | 39 | 39 | 39 | 39 |
Maximum vertical flue length 80/125 | m | 41 | 41 | 41 | 41 |